Problem:
The message "Motor protection relay tripped" appears on the monitor.

Solution:
The motor circuit breaker has tripped, possibly due to a missing phase or machine overload.
Check the power supply to see if a phase is missing and/or the voltage selector plug (number 4) is in the correct position.
Switch off the machine and open the cover of the control box.
Locate the motor protection switch F1.1/K1M under number 5 and switch the motor protection switch back on.

Switch the device on again and check whether the error message occurs again.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article